产品简介:

The Series 600 Angular Displacement Transducers (ADT’s) are precision differential capacitors. These transducers do not have the edge effects and dimensional instability characteristic of traditional capacitive devices. The sensing element is coupled to a solid state oscillator, demodulator, and amplifier to yield DC input – DC output performance.

产品详情
文件下载
KEY FEATURES
  • Ranges from ±30º to ±60º
  • DC Voltage Operation
  • Non-linearity < 0.05%
  • Absolute Measurement

SPECIFICATIONS

MODEL NO. DISPL. RANGE
+CW, -CCW
LINEARITY* MAX. USABLE RANGE LINEARITY USABLE RANGE OUTPUT VDC INPUT/ OUTPUT CURVE TYPICAL TEMP. COEF. SPAN/ °F
0600-0000 ±30° ±0.05% ±40° ±0.10% 100 mV/° 1 -0.01%
0601-0000 10°-70° CW ±0.05% 0°-80° CW ±0.10% 100 mV/° 2 -0.015%
0602-0000 10°-70° CCW ±0.05% 0°-80° CCW ±0.10% 100 mV/° 3 -0.01%
0603-0000 ±60° ±0.10% ±80° ±0.15% 100 mV/° 4 -0.01%
0603-0001 ±60° ±0.05% ±80° ±0.10% 100 mV/° 4 -0.01%
0603-0002 20°-140° CW ±0.10% 0°-160° CW ±0.15% 50 mV/° 5 -0.015%
0603-0003 20°-140°CW ±0.05% 0°-160° CW ±0.10% 50 mV/° 5 -0.015%
0603-0004 20°-140° CCW ±0.10% 0°-160° CCW ±0.15% 50 mV/° 6 -0.01%
0603-0005 20°-140° CCW ±0.05% 0°-160° CCW ±0.10% 50 mV/° 6 -0.01%

*Definition: Zero Base Terminal Average, expressed as a max % deviation of total range. CW defined as clockwise direction of shaft rotation, when viewed from shaft end.

COMMON ELECTRICAL SPECIFICATIONS

REPEATABILITY < .01% INTERNAL CARRIER FREQUENCY 400 KHz
RESOLUTION Infinite RIPPLE, MAX. 20 mV P/P 400 KHz
CURRENT, INPUT 30 mA Max. ZERO ADJUSTMENT ±3°
IMPEDANCE, OUTPUT < 2 Ohms ZERO POSITIONS See Output Curves
MAX. ANGULAR VELOCITY 1,440°/sec FREQUENCY RESPONSE > 1500 Hz
MAX. ANGULAR VELOCITY
with output down < 2%
18,000°/sec available
(see “Ordering
Information”, pg. 53)
EXCITATION VOLTAGE
Input > 18 VDC may damage unit
15.00 VDC
(see options, pg. 53)
INPUT POLARITY PROTECTED OUTPUT SHORT CIRCUIT PROTECTED

REMOTE ZERO OPERATION

trans-2016-600-remote-zero

Unless operating in a noise free environment, the lead to pin C must be shielded, as shown. The existing zero adjusted potentiometer in the Angular Displacement Transducer must be rotated fully clockwise before the remote zero control can function correctly. This remote zero control can function correctly. This remote function is useful in applications where it is inconvenient to access the adjustment screw on the transducer housing.