Type BLC B1 ... Maximum capacity (Emax) (Load introduction = count |
erbore + thread) |
BLC B1 D1 / ... 550 kg; 1.1 t; 1.76 t |
BLC B1 C3 / ... 550 kg; 1.1 t; 1.76 t |
|
Accuracy class according to OIML R60 Maximum number of LC intervals (nLC) |
D1 1000 |
C3 3000 |
||
Minimum LC verification interval (vmin) |
% of Emax |
0.0285 |
0.0090 (550 kg + 1.1 t) 0.0100 (1.76 t) |
|
Sensitivity (CN) |
mV/V |
1.94 |
||
Sensitivity tolerance |
% |
"0.5 |
"0.1 |
|
Temperature effect on zero balance (TK0) |
% of Cn / 10 K |
"0.0400 |
"0.0140 |
|
Temperature effect on sensitivity (TKC) |
"0.0500 |
"0.0140 |
||
Hysteresis error (dhy) |
% of Cn |
"0.0500 |
"0.0170 |
|
Non-linearity (dlin) |
"0.0500 |
"0.0170 |
||
Creep (dcr) over 30 min. |
"0.0500 |
"0.0166 |
||
Input resistance (RLC) |
Ω |
> 350 |
||
Output resistance (R0) |
350 "2 |
|||
Reference excitation voltage (Uref) |
V |
5 |
||
Nominal range of excitation voltage (BU) |
0.5 ... 15 |
|||
Insulation resistance (R is) |
GΩ |
> 5 |
||
Nominal temperature range (BT) |
。C [。F] |
−10 ... +40 [+14 ... +104] |
||
Service temperature range (Btu) |
−30 ... +70 [−22 ... +158] |
|||
Storage temperature range (B tl) |
−50 ... +85 [−58 ... +185] |
|||
Safe load limit (EL) |
% of Emax |
150 |
||
Lateral load limit (Elq) |
100 |
|||
Breaking load (Ed) |
300 |
|||
Permissible dynamic load (Fsrel) (vibration amplitude according to DIN 50100) |
70 |
|||
Deflection at Emax (snom), approx. |
mm |
0.5 (1.76 t = 1.4 mm) |
||
Weight (G), approx. |
kg |
0.9 |
||
Protection class to EN 60 529 EN 60 529 (IEC 529) |
IP67 |
|||
Material: Measuring element Cable fitting Gasket Cable-sheath Application protection (sealing) |
Stainless steel Stainless steel Viton® PVC Silicone |
3) The data for Non-linearity (dlin