Parameter | Unit of measure | Specification | |||||
Model No. | SLC611D POWERCELL® 5) | ||||||
Rated capacity (R .C .) | t (lb) nominal | 7.5 (17000) | 15 (33000) | 22.5 (50000) | |||
Min . increment size, typical8) | kg (lb) | 0.15 (0.33) | 0.3 (0.66) | 0.45 (1) | |||
Zero load output | %R.C. | <0.5 | |||||
Combined error1) 2) | %R.C. | C3/IIIM n:5: ≤ 0.018 | |||||
Repeatability error | %A.L.3) | C3/IIIM n:5: ≤ 0.01 | |||||
Creep, 30 minute | %A.L. | C3/IIIM n:5: ≤ 0.017 | |||||
Min . dead load output retrun (DR), 30 min | %A.L. | C3/IIIM n:5: ≤ 0.017 | |||||
Temperature effect on | %R .C ./°C ( . ./°F) | 0.0014 (0.0008) | |||||
%A.L ./°C ( . ./°F) | C3/IIIM n:5: ≤ 0.001 (0 .0006) | ||||||
Temperature range | Compensated Operating Safe storage |
°C (°F) | - 10 to +40 (+14 to +104) | ||||
-40 to +55 (-40 to +131) | |||||||
-40 to +80 (-40 to +176) | |||||||
OIML / European approval4) | R60/2000-CN1- 15 .03 / NMi TC8738 | ||||||
C3 | |||||||
3000 | |||||||
kg | 0.83 | 1.67 | 2.5 | ||||
0.8 | |||||||
CH | |||||||
kg | 50 | ||||||
3000 | |||||||
None | |||||||
NTEP approval4) |
Number
Min. dead load |
15.046 | |||||
lll M n:5 | |||||||
5000 | |||||||
lb | 2.2 | 4.2 | 6.3 | ||||
lb | 110 | ||||||
ATEX approval4) | Cat. 2 Cat. 3 |
II 2 G Ex ib IIB T4 Gb / II 2 D Ex ib IIIC T130 C Db / -40°C ≤ Ta≤ +55°C | |||||
II 3 G Ex ec IIC T6 Gc; II 3 G Ex nA IIC T6 Gc; II 3 D Ex tc IIIC T85°C Dc; Ta = -40ºC to +55ºC; Type, IP65 | |||||||
IECEx approval4) | Ex ib IIB T4 Gb / Ex ib IIIC T130°C Db / -40ºC ≤ Ta ≤ +55ºC Ex ec IIC T6 Gc; Ta =-40°C to +55°C, IP65 / Ex nA IIC T6 Gc; Ta = -40°C to +55°C, IP65 / Ex tc IIIC T85°C, Ta = -40°C to +55°C, IP65 |
||||||
Factory mutual approval4) |
Div 1 US Div 1 Canada Div 2 US Div 2 Canada |
IS / I, II, III / 1 / CDEFG / T4 Ta = -40°C to 55°C ; I / 1 / AEx ib / IIB / T4 Ta = -40°C to 55°C / Gb ; 21 / AEx ib / IIIC / T130°C Ta = -40°C to 55°C / Db | |||||
IS / I, II, III / 1 / CDEFG / T4 Ta = -40°C to 55°C ; 1 / Ex ib / IIB / T4 Ta = -40°C to 55°C; Gb ; 21 / Ex ib / IIIC / T130°C Ta = -40°C to 55°C; Db | |||||||
NI / I,II,III / 2 / CDFG/T6 Ta= -40°C to +55°C ; Class I Zone 2 IIB, T6, Zone 22 IIIB T85° Ta= 40°C to +55°C NI / I, II,III Division 2, Groups A, B, C, D, F G; T6 Ta = -40°C to +55°C ; Class I, Zone 2, Group IIC, T6 Zone IIIB T85°C Ta = -40°C to +55°C |
|||||||
NNI / I,II,III / 2 / CDFG/T6 Ta= -40°C to +55°C ; NI / I,II,III / 2 / ABCDFG/T6 Ta= -40°C to +55°C | |||||||
Supply non-regulated |
Range (nominal) Typical |
V DC | 7.5 ~ 25 | ||||
12-24 | |||||||
Supply current | Max . Typical |
mA | 200 | ||||
20 | |||||||
Overcurrent due to lightning: Max . tested on IEC62305- 1 |
A | 2500 (no direct flash) | |||||
Warm-up time from cold start | minutes | 5 | |||||
Communications | Type Protocol |
Controller Area Network (CAN), encrypted | |||||
Can Open | |||||||
Effective system update rate (4 load cells) | Hz | 100 | |||||
ESD rating | kV | 8 | |||||
Span stability, typical (peak to peak in 1 min) | Counts | 15 | |||||
Immunity OIML R60 | V/m | 10 | |||||
Material | Spring element Enclosure Connectors Cable |
Stainless steel | |||||
304 Stainless steel, electropolished | |||||||
Stainless steel | |||||||
Polyurethane (PU) | |||||||
Protection | Type IP rating NEMA rating |
Welded | |||||
IP68/IP69K | |||||||
NEMA 6/6P | |||||||
Load limit | Safe Ultimate |
%R.C. | 200 | ||||
300 | |||||||
Safe dynamic load | %R.C. | 70 | |||||
Fatigue life | cycles @ R .C . | > 1,000,000 | |||||
Direction of loading | Compression | ||||||
Restoring force5) | A% .L ./mm ( . ./in)3) |
2.4 (61) | 3.4 (87) | ||||
Max . horizontal travel6) | mm (in) | 8 (0 .31) | 7 (0 .27) | 5 (0 .2) | |||
Deflection @ R .C ., nominal | mm (in) | 0.2 (0 .008) | 0.37 (0 .015) | 0.49 (0 .019) | |||
Weight, nominal | kg (lb) | 1.2 (2 .6) | |||||
Load cell cable6) Cable Home-run cable6) |
Polyurethane, 30mm connector | ||||||
Polyurethane, 6 .2mm jacket | |||||||
Connectors | Quick-Connect |